4. To construct a calibration graph for determining indium in semiconductor gallium, standard solutions were prepared and the limiting diffusion current was measured (device sensitivity 1/25):
Indium concentration, µg/10 ml 0.2 0.4 0.6 1.0
Limit current, µA 2.3 4.8 6.3 11.4
A 0.35 g sample of gallium was dissolved and, after appropriate treatment, the solution was diluted with water to 50 ml. With a device sensitivity of 1/10, the indium wave height turned out to be 9.5 µA. Determine the percentage of indium in gallium.
If you cannot open the file or have any problems, do not rush to leave a negative review! Contact me and I will quickly help you solve the problem. After purchasing, please leave a positive review of the product :)
No feedback yet